Predator EditLock™ Hardware

Predator EditLock Hardware

What is a Predator EditLock?

Predator EditLock Hardware is an affordable machine Edit control. Predator EditLocks can be controlled via software or hardware and are easy to install. It includes magnetic mounting and I/O cable. It supports a wide range of machines. Input voltage levels can vary per digital input, but should match the machine. Choose from the following base voltage configurations:

  • 5 Volt DC
  • 12 Volt DC
  • 24 Volt DC

Why use Predator EditLock?

  • Lock or unlock Edit Start button via software
  • Lock or unlock Edit Start button via digital I/O
  • Supports Predator DNC
  • Supports Predator MDC
  • Supports Predator RCM
  • Supports Predator Touch HMI
  • Supports Predator BCRs
  • Supports Predator MDC Adapters
  • Supports Predator Grizzly Cables
  • Optionally use existing RS232 cables
  • Open Architecture - Not Proprietary

Installation of Predator EditLocks

Electrical Signal Wiring

Experienced electricians or maintenance personnel are responsible for identifying electrical signals for edit, cycle start, machine alarm and other signals as desired. These signals must be labeled and wired to an orange Wago connector that is included with every Predator EditLock. The orange Wago connector establishes a line of demarcation. Customers are responsible for wiring machine signals to the female Wago connector. When Predator Onsite Services are utilized, Predator Field Service personnel are responsible for wiring, operation and installation of the Predator EditLock up to the male orange Wago connector. This line of demarcation establishes a single border of responsibility and addresses any concerns over warranty, installation and operation. Predator EditLocks operate as a separate isolated 24 volt DC based circuit from the CNC machine, robot or CMM.

Predator EditLock Hardware Specifications

General  
Operating System Embedded
Interfaces 2 Serial Ports
Operating Voltage 24 Volt DC
Standard I/O 8 Digital Inputs and 6 Digital Outputs
Operating Temperature 32 - 131°F or 0 - 55°C
Relative Humidity 5 - 90% Non Condensing
Altitude 0 - 12,000 ft or 0 - 3660 Meters
Safety UL 1950, EN60950, CSA 22.2, No. 950
Emissions/Immunity EN55011:1998 Class A
Expansion Up to 8 Digital or Analog Modules
RoHS Compliant Yes
I/O Expansion Options  
Digital Inputs Up to 64 DC Inputs (5v, 12v, 24v, 48v, 60v, 110v or 230v)
Digital Outputs Up to 64 DC Outputs (24v)
Analog Inputs Up to 32 DC Inputs (0v - 10v)
Low Voltage Inputs Up to 32 DC Inputs (0v - 10v)
Power  
Circuit Breaker Yes
International Power Supply Yes (100 - 240 Volt)
Power Options US, POE, 15 AMP Twist Lock, 20 AMP Twist Lock, EU, AU or UK style
Input Voltage Range 85 - 264 Volts AC
Output Voltage 24 Volts DC 0.5 Amps

Predator EditLock - Part Numbers

Part # Description for Domestic Items
60020000 Predator EditLock - Voltage and Power To Be Determined
60021005 Predator EditLock - 5 Volt DC with US power
60021012 Predator EditLock - 12 Volt DC with US power
60021024 Predator EditLock - 24 Volt DC with US power
60025005 Predator EditLock - 5 Volt DC with 15A Twist Lock power
60025012 Predator EditLock - 12 Volt DC with 15A Twist Lock power
60025024 Predator EditLock - 24 Volt DC with 15A Twist Lock power
60026005 Predator EditLock - 5 Volt DC with 20A Twist Lock power
60026012 Predator EditLock - 12 Volt DC with 20A Twist Lock power
60026024 Predator EditLock - 24 Volt DC with 20A Twist Lock power
Part # Description for Power Over Ethernet Items
60027005 Predator EditLock - 5 Volt DC with POE
60027012 Predator EditLock - 12 Volt DC with POE
60027024 Predator EditLock - 24 Volt DC with POE
Part # Description for International Items
60022005 Predator EditLock - 5 Volt DC with EU power
60022012 Predator EditLock - 12 Volt DC with EU power
60022024 Predator EditLock - 24 Volt DC with EU power
60023005 Predator EditLock - 5 Volt DC with UK power
60023012 Predator EditLock - 12 Volt DC with UK power
60023024 Predator EditLock - 24 Volt DC with UK power
60024005 Predator EditLock - 5 Volt DC with AU power
60024012 Predator EditLock - 12 Volt DC with AU power
60024024 Predator EditLock - 24 Volt DC with AU power

NOTE: The above units are recommended for serial based implementations with mounting in existing machine cabinets.

Predator Armor Enclosure and Predator EditLock - Part Numbers

Part # Description for Domestic Items
80020000 Predator Armor Enclosure and EditLock - Voltage and Power To Be Determined
80021005 Predator Armor Enclosure and EditLock - 5 Volt DC with US power
80021012 Predator Armor Enclosure and EditLock - 12 Volt DC with US power
80021024 Predator Armor Enclosure and EditLock - 24 Volt DC with US power
80025005 Predator Armor Enclosure and EditLock - 5 Volt DC with 15A Twist Lock power
80025012 Predator Armor Enclosure and EditLock - 12 Volt DC with 15A Twist Lock power
80025024 Predator Armor Enclosure and EditLock - 24 Volt DC with 15A Twist Lock power
80026005 Predator Armor Enclosure and EditLock - 5 Volt DC with 20A Twist Lock power
80026012 Predator Armor Enclosure and EditLock - 12 Volt DC with 20A Twist Lock power
80026024 Predator Armor Enclosure and EditLock - 24 Volt DC with 20A Twist Lock power
Part # Description for Power Over Ethernet Items
80027005 Predator Armor Enclosure and EditLock - 5 Volt DC with POE
80027012 Predator Armor Enclosure and EditLock - 12 Volt DC with POE
80027024 Predator Armor Enclosure and EditLock - 24 Volt DC with POE
Part # Description for International Items
80022005 Predator Armor Enclosure and EditLock - 5 Volt DC with EU power
80022012 Predator Armor Enclosure and EditLock - 12 Volt DC with EU power
80022024 Predator Armor Enclosure and EditLock - 24 Volt DC with EU power
80023005 Predator Armor Enclosure and EditLock - 5 Volt DC with UK power
80023012 Predator Armor Enclosure and EditLock - 12 Volt DC with UK power
80023024 Predator Armor Enclosure and EditLock - 24 Volt DC with UK power
80024005 Predator Armor Enclosure and EditLock - 5 Volt DC with AU power
80024012 Predator Armor Enclosure and EditLock - 12 Volt DC with AU power
80024024 Predator Armor Enclosure and EditLock - 24 Volt DC with AU power

NOTE: The above units are recommended for serial based implementations.

Predator Armor Enclosure, 2 Port Express/W and EditLock - Part Numbers

Part # Description for Domestic Items
83020000 Predator Armor Enclosure, 2 Port Express/W and EditLock - Voltage and Power To Be Determined
83021005 Predator Armor Enclosure, 2 Port Express/W and EditLock - 5 Volt DC with US power
83021012 Predator Armor Enclosure, 2 Port Express/W and EditLock - 12 Volt DC with US power
83021024 Predator Armor Enclosure, 2 Port Express/W and EditLock - 24 Volt DC with US power
83025005 Predator Armor Enclosure, 2 Port Express/W and EditLock - 5 Volt DC with 15A Twist Lock power
83025012 Predator Armor Enclosure, 2 Port Express/W and EditLock - 12 Volt DC with 15A Twist Lock power
83025024 Predator Armor Enclosure, 2 Port Express/W and EditLock - 24 Volt DC with 15A Twist Lock power
83026005 Predator Armor Enclosure, 2 Port Express/W and EditLock - 5 Volt DC with 20A Twist Lock power
83026012 Predator Armor Enclosure, 2 Port Express/W and EditLock - 12 Volt DC with 20A Twist Lock power
83026024 Predator Armor Enclosure, 2 Port Express/W and EditLock - 24 Volt DC with 20A Twist Lock power
Part # Description for Power Over Ethernet Items
83027005 Predator Armor Enclosure, 2 Port Express/W and EditLock - 5 Volt DC with POE
83027012 Predator Armor Enclosure, 2 Port Express/W and EditLock - 12 Volt DC with POE
83027024 Predator Armor Enclosure, 2 Port Express/W and EditLock - 24 Volt DC with POE
Part # Description for International Items
83022005 Predator Armor Enclosure, 2 Port Express/W and EditLock - 5 Volt DC with EU power
83022012 Predator Armor Enclosure, 2 Port Express/W and EditLock - 12 Volt DC with EU power
83022024 Predator Armor Enclosure, 2 Port Express/W and EditLock - 24 Volt DC with EU power
83023005 Predator Armor Enclosure, 2 Port Express/W and EditLock - 5 Volt DC with UK power
83023012 Predator Armor Enclosure, 2 Port Express/W and EditLock - 12 Volt DC with UK power
83023024 Predator Armor Enclosure, 2 Port Express/W and EditLock - 24 Volt DC with UK power
83024005 Predator Armor Enclosure, 2 Port Express/W and EditLock - 5 Volt DC with AU power
83024012 Predator Armor Enclosure, 2 Port Express/W and EditLock - 12 Volt DC with AU power
83024024 Predator Armor Enclosure, 2 Port Express/W and EditLock - 24 Volt DC with AU power

NOTE: Predator Express/W style units are recommended for wireless Ethernet based implementations.

Predator Armor Enclosure, DR 2x2 and Predator EditLock - Part Numbers

Part # Description for Domestic Items
87020000 Predator Armor Enclosure, DR 2x2 and EditLock - Voltage and Power To Be Determined
87021005 Predator Armor Enclosure, DR 2x2 and EditLock - 5 Volt DC with US power
87021012 Predator Armor Enclosure, DR 2x2 and EditLock - 12 Volt DC with US power
87021024 Predator Armor Enclosure, DR 2x2 and EditLock - 24 Volt DC with US power
87025005 Predator Armor Enclosure, DR 2x2 and EditLock - 5 Volt DC with 15A Twist Lock power
87025012 Predator Armor Enclosure, DR 2x2 and EditLock - 12 Volt DC with 15A Twist Lock power
87025024 Predator Armor Enclosure, DR 2x2 and EditLock - 24 Volt DC with 15A Twist Lock power
87026005 Predator Armor Enclosure, DR 2x2 and EditLock - 5 Volt DC with 20A Twist Lock power
87026012 Predator Armor Enclosure, DR 2x2 and EditLock - 12 Volt DC with 20A Twist Lock power
87026024 Predator Armor Enclosure, DR 2x2 and EditLock - 24 Volt DC with 20A Twist Lock power
Part # Description for Power Over Ethernet Items
87027005 Predator Armor Enclosure, DR 2x2 and EditLock - 5 Volt DC with POE
87027012 Predator Armor Enclosure, DR 2x2 and EditLock - 12 Volt DC with POE
87027024 Predator Armor Enclosure, DR 2x2 and EditLock - 24 Volt DC with POE
Part # Description for International Items
87022005 Predator Armor Enclosure, DR 2x2 and EditLock - 5 Volt DC with EU power
87022012 Predator Armor Enclosure, DR 2x2 and EditLock - 12 Volt DC with EU power
87022024 Predator Armor Enclosure, DR 2x2 and EditLock - 24 Volt DC with EU power
87023005 Predator Armor Enclosure, DR 2x2 and EditLock - 5 Volt DC with UK power
87023012 Predator Armor Enclosure, DR 2x2 and EditLock - 12 Volt DC with UK power
87023024 Predator Armor Enclosure, DR 2x2 and EditLock - 24 Volt DC with UK power
87024005 Predator Armor Enclosure, DR 2x2 and EditLock - 5 Volt DC with AU power
87024012 Predator Armor Enclosure, DR 2x2 and EditLock - 12 Volt DC with AU power
87024024 Predator Armor Enclosure, DR 2x2 and EditLock - 24 Volt DC with AU power

NOTE: Predator DR 2x2 style units are recommended for wired Ethernet based implementations.